The Rooster™ Airflow Alarm & Monitor platform harnesses the airflow engineering expertise of degreeC to provide users with a reliable, high-accuracy, hassle-free safety compliance (NSF/ANSI-49 & OSHA) solution for laboratories, clean rooms, and critical ventilation systems. With the latest generation of the Rooster product family, users can fully configure their airflow safety and monitoring experience to meet the specific needs of their facilities.

Rooster Airflow Alarm

Designed as a simple retrofit option for fume hoods and biosafety cabinets, The Rooster™ is a fast, reliable, and affordable way to monitor airflow safety and achieve OSHA or NSF-49/ANSI compliance. The Rooster™ Alarm provides full time tracking of air velocities within cabinet or exhaust systems to ensure air movement never falls below user-defined thresholds.

One-step push-button calibration
Quick and easy installation and alarm setup
Choice of Airflow Sensor
Probe, sidewall, or inline sensor styles available
Auxiliary Night Setback Input
Facility-wide energy savings
Configurable Alarm Behaviors
Customizable alarm tones, warning lights and latching or reset behaviors
 
Features
  • One-step push-button calibration
  • Customizable audible alarm tones and warning lights
  • Latching or resettable alarm
  • Configurable Alarm Threshold (ships with NSF/ANSI-49 required -20%)
  • Facility Night Set-Back feature available
  • Available with probe, sidewall and inline sensor options
  • Private labeling options available
  • 12′ sensor cable for probe, 4′ sensor cable for sidewall
Specifications
  • Operating Temperature: 60°F to 140°F (15°C to 60°C)
  • Storage Temperature:: -40°F to 185°F (-40°C to 85°C)
  • Relative Humidity (non-condensing): 5-95%
  • Air Velocity Range: 0.20-10.0m/s (40-2,000fpm)
  • Response Time: <1 Second
  • Supply Voltage 12-24 VDC
  • Input Current: 0.5A Max
 
Rooster Airflow Monitor 100

The Rooster™ Monitor100 is the next-generation airflow monitoring and alarm system for critical containment applications, including chemical fume hoods, biological safety cabinets, laminar flow hoods and other applications where airflow is required to be viewed, monitored, alarmed, logged and communicated to building and laboratory systems.

Fast Intuitive Setup
This video guide will get you from boot-up through the initial calibration procedure.
Dynamic Alarming
Whole-screen background colorization to convey current state augmented by flashing red LED while in alarm state.
Multiple Sensor Options
Accepts side-flow sensor for negatively pressurized cabinets, insertion probe for exhaust ducts and inline retrofit design to replace legacy airflow alarm monitors.
Responsive Touch
Built for laboratory professionals, the built-in LCD screen of the Rooster™ Monitor100­ works with or without gloves.
Enhanced Security
Dual password protection allows users to personalize operational experience, but not override safety features set by facility managers.
Easy Upgrade Procedure
USB port allows for in-the-field firmware updates.
Features
  • Glove-friendly, color touch panel display
  • Whole-screen background colorization to convey current state, augmented by flashing red LED while in alarm state
  • Instrumentation-class sensor, compatible with latest 2014 NSF requirements for repeatability and high accuracy calibration.
  • Volume and tone control
  • Accepts side-flow sensor for negatively pressurized cabinets, insertion probe for exhaust ducts and inline retrofit design to replace legacy airflow alarm monitors
  • Full temperature compensation built-in for accuracy across wide operating temperature range
  • Air temperature sensing included and displayed on-screen
  • Wide velocity range capability, for use in face-velocity or duct-velocity applications
  • Fast and intuitive set-up, with no need to have manual on hand.
  • Event logging with fast USB download
  • Dual password protection allows users to personalize operational experience, but not override safety features set by facility managers.
  • Upgradeable firmware, in-the-field via USB bootloader
Specifications
  • LCD Display Area: 57mm x 70mm (2.30in x 2.7in)
  • Air Velocity Range: 0.15 – 10.0 m/s (30-2,000 fpm)
  • Velocity Repeatability: 1% (NSF49:2014 Requirement)
  • Response Time: < 1 Second
  • Supply Voltage: 24 VAC/VDC & Wall Adapter
  • Red LED Indicator: 160° Viewing Angle
  • Alarm Volume: 0 – 85dB (Adjustable)
  • Relative Humidity: 5 – 95% (Non-Condensing)
  • Operating Temperature: 5°C – 60°C (40°F – 140°F)
  • Storage Temperature: -40°C – 85°C (-40°F – 185°F)
  • Compliance Standards: CE, RoHS
Rooster Air Sensor 100

The Rooster™ Sensor100 is a next-generation air velocity and temperature sensor with a built-in touchscreen display for configuring alarm set points and output behavior. Using an instrumentation grade sensing element, the Sensor100 comes calibrated and ready to deploy. With its user-friendly, color touch-screen interface, the Sensor100 can be set-up into your building or system with unprecedented ease.

Responsive Touch
Built for laboratory professionals, the built-in LCD screen of the Rooster™ Sensor100­ works with or without gloves.
Enhanced Security
Dual password protection allows users to personalize operational experience, but not override safety features set by facility managers
Probe Style Sensor
Easy-to-install, single-hole mounting procedure with no need for hands inside the duct. Available with either a gland or clamp-style fitting.
Easy Upgrade Procedure
USB port allows for in-the-field firmware updates
Features
  • Glove-friendly, color touch panel display
  • Whole-screen background colorization to convey current state, augmented by flashing red LED while in alarm state
  • Instrumentation-class sensor, compatible with latest 2014 NSF requirements for repeatability and high accuracy calibration.
  • Accepts side-flow sensor for negatively pressurized cabinets, insertion probe for exhaust ducts and inline retrofit design to replace legacy airflow alarm monitors
  • Full temperature compensation built-in for accuracy across wide operating temperature range
  • Air temperature sensing included and displayed on-screen
  • Wide velocity range capability, for use in face-velocity or duct-velocity applications
  • Fast and intuitive set-up, with no need to have manual on hand.
  • Dual password protection allows users to personalize operational experience, but not override safety features set by facility managers.
Specifications
  • LCD Display Area: 57mm x 70mm (2.30in x 2.7in)
  • Air Velocity Range: 0.15 – 10.0 m/s (30-2,000 fpm)
  • Velocity Repeatability: 1% (NSF49:2014 Requirement)
  • Response Time: < 1 Second
  • Supply Voltage: 24 VAC/VDC & Wall Adapter
  • Red LED Indicator: 160° Viewing Angle
  • Alarm Volume: 0 – 85dB (Adjustable)
  • Relative Humidity: 5 – 95% (Non-Condensing)
  • Operating Temperature: 5°C – 60°C (40°F – 140°F)
  • Storage Temperature: -40°C – 85°C (-40°F – 185°F)
  • Compliance Standards: CE, RoHS
Rooster Air Pressure Monitor 100

The Rooster™ Pressure100 is a next-generation air pressure, temperature and humidity monitor with a user-friendly touchscreen interface for configuring alarm set points and output behavior. The Rooster™ Pressure100 is designed to meet the monitoring guidelines for USP 797 & USP 800, as well as FDA guidelines for 503a/503b compounding pharmacies. With it’s datalogging capabilities, the Pressure100 is also suitable for clean rooms, laboratories, vivariums, hospitals, and general critical containment facilities.

Real-Time Sensor Values On-Screen
Air pressure, temperature and humidity readings are displayed on an intuitive LCD touchscreen interface.
Dynamic Alarming
With the Rooster Pressure100, real-time fluctuations in pressure or temperature are flagged with background screen color shifts to indicate changes in safety status based on user-defined thresholds. Active alarms are augmented with a flashing red LED.
Responsive Touch
Built for laboratory professionals, the  LCD touchscreen interface of the Rooster™ Pressure100­ works with or without gloves.
Enhanced Security
Dual password protection allows users to personalize operational experience, but not override safety features set by facility managers.
Easy Upgrade Procedure
USB port allows for in-the-field firmware updates.
Features
  • Glove-friendly, color touch panel display
  • Whole-screen background colorization to convey current state, augmented by flashing red LED while in alarm state
  • Room differential pressure, available in inches of Water, cm of water or Pascals, displayed on-screen with alarming capabilities
  • Configurable door status alarm during real-time pressure drops
  • Full temperature compensation built-in for accuracy across wide operating temperature range
  • Displays measured air temperature & humidity on-screen
  • Door intrusion alarm and event logging
  • Environmental data logging with USB download
  • Fast and intuitive set-up, with no need to have manual on hand.
  • Dual password protection allows users to personalize operational experience, but not override safety features set by facility managers.
Specifications
  • Differential Pressure Range: -125 to +125 Pa (-0.5 to 0.5 in H2O)
  • Accuracy: 3% of reading, 0.08 Pa (0.00032 in H2O)
  • Repeatability: 0.5% of reading, 0.04 Pa (0.00016 in H2O)
  • Temperature Measurement Range: -40°F – 185°F (-40°C – 85°C)
  • Supply Voltage: 24 VAC/VDC & Wall Adapter
  • Red LED Indicator: 160° Viewing Angle
  • Alarm Volume: 0 – 85dB (Adjustable)
  • Compliance Standards: CE, RoHS