For temporary isolation of a person or infected item
Overview:
The IsoArk N 36-6 Isolation Chamber is an ideal temporary solution to rapidly isolate a person or an item that is thought to be contaminated by infectious particles or diseases before moving them to an isolated area for safe treatment.
The isolation chamber is equipped with its own negative pressure filtration system to provide maximum protection and operational safety for both the contaminated person or item and the operational team
SYSTEM FEATURES:
Description:
The IsoArk N 36-6 Isolation Chamber is assembled and ready for use within minutes. The unit can operate on workshop or laboratory floors as a stand-alone unit or be secured onto a flat surface such as a bed, workbench, trolley, or stretcher.
The N 36-6 is unique in its ability to maintain isolation in multiple patient positions and can utilize built-in stretcher belting for safe and secure patient transport. The air entering the N 36-6 Isolation Chamber passes through the first HEPA filter, filtering the air for the patient, and then exits to the general public through another HEPA filter, preventing the spread of contamination. Additional advantages of the IsoArk N 36-6 include the ability to use any type of glove that the end user might require. The unit has a double zipped pouch, which acts as a mini airlock and allows the safe transfer of objects in and out of the chamber (for example, medicine, paperwork, etc.), without the threat of spreading contamination. The blower is equipped with a battery back-up that allows the system to be independent of an external power source for up to 10 hours (with full charge). The chamber liner is made from a special material and strengthened by inserting aluminium poles along each side of the structure and the ‘all around’ zipper system allows the chamber to be opened completely, giving easy operator accessibility.
The N 36-6 has four integrated zipped glove portals on each side for internal working access while the chamber is closed and four small, zipped portals are integrated into the liner, which are used for infusions, catheter equipment, etc. When not in use, the entire system can be easily dismantled and folded for very compact storage.
APPLICABLE STANDARDS:
Posture forming structure for the comfort of patients and medical personnel
Additional advantages include the ability to use any type of glove that is required
Additional utility bar for mounting diagnostic equipment
Air entering the chamber passes through a HEPA filter and then exits through another HEPA filter to prevent spreading contamination